APC Netshelter Metered Rack PDU, 0U, Clipsal 56 Series Input, 6x IEC C19 & 36x IEC C13 Outlets
Rack PDU 2G, Metered, ZeroU, 32A, 230V, Clipsal 56 series AS/NZ input plug, (36) C13 & (6) C19 outlets
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using StruxureWare software suite.
Main Input Voltage 200 V 208 V 230 V
PDU type Metered
Main Output Voltage 230 V
Number of rack unit 0U
Cable length 3.00 m
Number of cables 1
Provided equipment- Installation guide, Rack mounting brackets, Serial configuration cable
Permissible voltage 220…240 V
Max line current 32 A
Input current limits 32 A
Network frequency 50/60 Hz
Number of input connectors 1 clipsal 32A 56P332
Number of power socket outlets- 36 IEC 60320 C13, 6 IEC 60320 C19
Ambient air temperature for operation -5…45 °C
Relative humidity 5…95 %
Operating altitude 0...10000 ft
Ambient air temperature for storage -25…65 °C
Storage Relative Humidity 5…95 %
Storage altitude 0.00…15240.00 m
Product certifications VDE
Mounting mode- Not rack mountable
Rack PDU 2G, Metered, ZeroU, 32A, 230V, Clipsal 56 series AS/NZ input plug, (36) C13 & (6) C19 outlets
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using StruxureWare software suite.
Main Input Voltage 200 V 208 V 230 V
PDU type Metered
Main Output Voltage 230 V
Number of rack unit 0U
Cable length 3.00 m
Number of cables 1
Provided equipment- Installation guide, Rack mounting brackets, Serial configuration cable
Permissible voltage 220…240 V
Max line current 32 A
Input current limits 32 A
Network frequency 50/60 Hz
Number of input connectors 1 clipsal 32A 56P332
Number of power socket outlets- 36 IEC 60320 C13, 6 IEC 60320 C19
Ambient air temperature for operation -5…45 °C
Relative humidity 5…95 %
Operating altitude 0...10000 ft
Ambient air temperature for storage -25…65 °C
Storage Relative Humidity 5…95 %
Storage altitude 0.00…15240.00 m
Product certifications VDE
Mounting mode- Not rack mountable
Shipping:
Free Shipping - Free Shipping over $1,000
Estimated Delivery Time:
Locations: We ship all over Australia. Sydney - New South Wales, Melbourne - Victoria, Brisbane - Queensland, Perth - Western Australia, Adelaide - South Australia, Canberra - Australian Capital Territory (ACT), Hobart - Tasmania, Darwin - Northern Territory
Return & Refund
Free Shipping - Free Shipping over $1,000
Estimated Delivery Time:
- Metro Areas: 4-12 business days
- Regional Areas: 7-14 business days
Return & Refund
- The item must be unused and in the same condition that you received it
- Returns are accepted within 30 days of delivery
- For any questions contact, support@goodmayesonline.com.au.
- Refund will be processed within 2-3 working days post-pickup.